Hysteresis Performance of CFT Columns subjected to Low Axial…

Emerging


4
Citations
0
Refs
2003
Year
Search Works
Work Details
  • OpenAlex ID W887463603
  • Type Article
  • Language EN
  • Published 01 Jan 2003
  • Volume 15 (2)
  • Pages 207–217
  • Source Journal of Korean Society of Steel Const…
  • Publisher Korean Society of Steel Constructio…
  • Added 10 Oct 2025
  • Updated 01 Oct 2026
MENU
0

Hysteresis Performance of CFT Columns subjected to Low Axial Force and Cyclic Lateral Loads

Article 2003 EN

The Concrete Filled Steel Tube (M) Column has excellent structural capacities that are in accordance with the interaction effect between the steel tube and concrete. CFT structure has been focussed on a struc tural system for high-rise buildings. The purpose of this study is to evaluate the strength and deformation capacities of CFT columns that are subject to constant axial and cyclic lateral loa…

4

Citations

0

References

3

Authors

0.00

FWCI

Citations by Year
Last 1 years
Topics
Keywords
UN Sustainable Development Goals
1 SDGs
Authors & Affiliations
3 authors
#AuthorInstitutionsORCID
1 Sung Mo Choi — —
2 Suk Bin Kang — —
3 Dae Joong Kim —

Data: OpenAlex